  • Function

    Packages built to promote heat recovery from flash steam, condensate or both. Especially recommended for heating a continuous flow of fluid, such as make-up water to a boiler feedwater system.

  • Use

    Steam, water, hot condensate and other fluids compatible with the construction.

  • Maximum allowable (primary) pressure

    up to 13 bar for saturated steam

  • Maximum allowable (primary) temperature

    for saturated steam: 250 ºC

  • Сondensate heating

    above 100 ºC

  • Steam boiler(s) perating pressure(s) and temperature

    boilers up to 20 bar – 220 ºC

  • Trap discharge capacity

    Max.: up to 50000 kg/h

  • Differential pressure on trap

    Delta P: 4,5 , 10 and 12 bar

  • Pipework pressure rating

    PN 16

  • Non-standard design

    Atmospherically vented units, to avoid extra back pressure in the condensate return system,
    Different types of materials and designs available, according to the application.

  • Connections

    Flanged EN 1092-1 PN 16,
    Flanged ASME B16.5 Class 150 on request

ADCATherm® Flash Steam Heat Recovery Unit ADCA FRECO

Код товару: FRECO

Доступно під запит

Ціна відповідно до конфігурації

Виберіть свою конфігурацію
Див. Вся конфігурація
Реф.#.
без ПДВ
(ОРІЄНТОВНА ЦІНА)

Кількість

-
+

Немає готових рішень

ADCATherm® Flash Steam Heat Recovery Unit ADCA FRECO

The ADCATherm FRECO flash steam heat recovery units are designed to facilitate heat recovery from flash steam, condensate or both.
The system is specially recommended for heating a continuous flow of fluid, such as make-up water to a boiler feed water system.
Non-continuous flow applications may require additional recirculation, relief valves, or other devices, to avoid system damage due to overheating and consequent overpressure.
It is known that the condensate return and its recovery are beneficial and ensure a remarkable energetic efficiency. However, the condensate, which is initially at high temperature, ends up expanding and losing most of its energy through the formation of flash steam. On the other hand, feed water temperatures higher than 90 ºC to the boiler feed pumps when coming from atmospheric vessels will normally cause cavitation with all the consequent damages.
The FRECO system prevents this problem since it is installed downstream of the pumps, using the high pressures which can be found there, allowing condensate heating above 100 ºC, without boiling, and naturally eliminating the chances of cavitation.

OPTIONS

Different types of materials and designs available, according to the application.

Atmospherically vented units, to avoid extra back pressure in the condensate return system.

ORDER REQUIREMENTS

Condensate flow rate and temperature.

Make-up water flow rate and temperature.

Operating pressures.

Steam boiler(s) capacity and operating pressure(s).