Dom Katalog Urządzenia parowe

Separatory przedmuchu kotłów / Zbiorniki chłodzące

Oczyścić

Pokazywać:
10 na stronę
  • 10 produktów na stronę
  • 25 produktów na stronę
  • 50 produktów na stronę
Sortować:
Relevance
  • Znaczenie
  • Utworzony w
  • Kod produktu
  • Nazwa
  • Dostępny
  • Valsteam ADCA

    A.75.2100.BV

    Product code: A.75.2100.BV

    Boiler blowdown expansion vessel ADCA BV

    • Function

      The boiler blowdown expansion vessels are designed for handling the short bursts of intermittent blowdown from the steam boiler and other hot water drains,
      They allow the flash steam to separate and to vent safely to the atmosphere through the exhaust head

    • Use

      Boiler blowdown and hot waste water

    • Body material

      Carbon steel or stainless steel

    • Max. operating pressure

      7 bar

    • Max. operating temperature

      180 ºC

    • Min. operating temperature

      20 ºC

    • Tank capacity, (L)

      BV3 – 249; BV4 – 373; BV5 – 598; BV6 – 978; BV7 – 1812

    • Supports

      Installation supporting feet floor

    • Non-standard design

      Water injection cooling system,
      Manifold with several inlets for multi-boiler installations,
      For non-standard models , please consult

    • Connections

      Flanged EN 1092-1 PN 16,
      Flanged ASME B16.5 Class 150 on request

    Wymiar:
    DN50 – DN200
    Price according to configuration
    Dostępne na prośbę
    Więcej o produkcie
  • Valsteam ADCA

    A.75.2050.000

    Product code: A.75.2050.000

    Boiler blowdown expansion and cooling unit ADCA BEX

    • Function

      Designed for handling the short bursts of intermittent blowdown from the steam boiler and other hot water drains.,
      They allow the flash steam to separate and to vent safely to the atmosphere through the exhaust head

    • Use

      Boiler blowdown and hot waste water

    • Body material

      Carbon steel or stainless steel

    • Max. operating pressure

      0,5 bar

    • Max. operating temperature

      120 ºC

    • Min. operating temperature

      -10 ºC

    • Tank capacity, (L)

      BEX15 – 22,9; BEX30 – 56,9; BEX40 – 92; BEX50 – 251; BEX60 – 393; BEX80 – 767

    • Supports

      Installation supporting feet floor

    • Non-standard design

      Flash steam condensing spray system.,
      Manifold with several inlets for multi-boiler installations.,
      Fitted with support brackets for elevated installation.,
      For non-standard models , please consult

    • Connections

      Flanged EN 1092-1 PN 16,
      Flanged ASME B16.5 Class 150 on request

    Wymiar:
    DN15 – DN150
    Price according to configuration
    Dostępne na prośbę
    Więcej o produkcie