Valsteam ADCA
Specyfikacje
-
Use
Drain and lift* steam condensate from heat exchangers, among others,
*Transfer, discharge, drain, filling, outlet, lifting -
Motive fluid (medium)
Saturated steam, compressed air, nitrogen and other gases
-
Pumped fluid (medium)
Steam condensate, diathermic oil, Diesel and petroleum products and other liquids compatible with the construction
-
Body material
Carbon steel – model APSTS,
Stainless steel – model APSTSS -
Motive inlet pressure
Max.: 10 bar,
Min.: 1 bar -
Fluid operating temperature
Max.: 185 °C,
Min.: 20 °C -
Trap discharge capacity
Max.: up to 16000 kg/h,
Min.: from 1800 kg/h -
Pump discharge capacity
Max.: up to 4580 kg/h,
Min.: from 1850 kg/h -
Pump discharge per cycle
22 (L) one volume for all dimension
-
Connections
Flanged* EN 1092-1 PN 16,
Flanged* ASME B16.5 Class 150, on request,
Female threaded ISO 7 Rp (threaded flanges*), on request,
*Check valves and welding neck counter flanges included